DPTA-PC
 Click to Zoom
Disable toilet alarm pull cord with two handles.

Pull Cords (DPTA-PC) are “Call Devices” which are ceiling mounted pull cords used to generate an alarm activation by a person in distress or requiring attention from a carer. When a call devices is activated the system will generate an alarm and the Remote Indicator (DPTA-RI) will illuminate & sound.

Power Supply
- Input Voltage: 12 VDC
- Quiescent Standby Current: 0mA
- Maximum Current During Alarm: 15 mA DC (Maximum)

User Operation
- Pull Card: Alarm Activation

LED
- Front Mounted
- System status: Alarm Activation
- Led response: Illuminates in Sympathy with System

Termination
Device is wired with 3 wires (positive, negative & signal) in and 3 wires (positive, negative & signal) out.

Housings
- White ABS