Bus module for system control
The JA-111H-AD TRB is designed for the connection of any control device (with contact or impulse outputs) to the JABLOTRON 100 system and provides it with a power supply from the control panel bus.
This built-in module can be directly integrated into the control device.
One input of the module has a fixed Tamper signal, several set signals can be selected for the second input and the third input serves either to report a fault of the connected device, or it can be used as the second control conductor with a fixed “Unset” signal.
The module can be used to control programmable PG outputs.
- It allows you to set a minimum activation time for the controller (0.1 s - 300 s).
- The detector features impulse activation for dual-conductor control as well as status control for single-conductor control.
- The module is a component of the JABLOTRON 100 system, is addressable and occupies one position in the system.
Specifications
- Compatible with: F-Link 1.4.0 or higher
- Power: via the control panel bus 12 V (9 - 15 V)
- Backup (idle) mode consumption: 5 mA + consumption of the control device
- Current consumption for cable selection : 12 mA + consumption of the control device
- Maximum acceptable load by the connected controller: 50 mA
- Dimensions: 16 x 30 x 12 mm
- Classification: security level 2 / environment class II
- In accordance with: EN 50131-1, EN 50131-3 (ACE type B)
- Operating temperature range: -10 to +40 °C
- It also meets the requirements of: EN 50130-4, EN 55022
The JA-111H-AD TRB is designed for the connection of any control device (with contact or impulse outputs) to the JABLOTRON 100 system and provides it with a power supply from the control panel bus.
This built-in module can be directly integrated into the control device.
One input of the module has a fixed Tamper signal, several set signals can be selected for the second input and the third input serves either to report a fault of the connected device, or it can be used as the second control conductor with a fixed “Unset” signal.
The module can be used to control programmable PG outputs.
- It allows you to set a minimum activation time for the controller (0.1 s - 300 s).
- The detector features impulse activation for dual-conductor control as well as status control for single-conductor control.
- The module is a component of the JABLOTRON 100 system, is addressable and occupies one position in the system.
Specifications
- Compatible with: F-Link 1.4.0 or higher
- Power: via the control panel bus 12 V (9 - 15 V)
- Backup (idle) mode consumption: 5 mA + consumption of the control device
- Current consumption for cable selection : 12 mA + consumption of the control device
- Maximum acceptable load by the connected controller: 50 mA
- Dimensions: 16 x 30 x 12 mm
- Classification: security level 2 / environment class II
- In accordance with: EN 50131-1, EN 50131-3 (ACE type B)
- Operating temperature range: -10 to +40 °C
- It also meets the requirements of: EN 50130-4, EN 55022