Interactive Fire Control Panel IFS7002 – one signal loop
Physical configuration:
- 1 fire alarm loop
- 2 monitored outputs
- 1 relay output for fire condition
- 1 programmable relay output for fire condition
- 1 relay output for fault conditions
Fire alarm zones:
- Maximum number of zones: 64
- Maximum number of fire detectors and in/out devices: 60
Fire alarm loop:
- Maximum number of fire detectors in a loop: 125
- Connecting line : two-wire shielded
- Maximum resistance of a loop: 100 ohm
- Output resistance of a loop: 20 ohm
- Maximum consumption of a loop: 200 mA
Monitored outputs: 2 pc
- Type: potencial
- Electrical characteristics: (24±5)V/0,5A
Relay output for fire conditions: 1 pc
- Type: potential free, switching
- Electrical characteristics: 3A/125VAC; 3A/30VDC
Relay (programmable) output for fire conditions: 1 pc
- Type: potential free, switching
- Electrical characteristics: 3A/125VAC; 3A/30VDC
Relay output for fault conditions: 1 pc
- Type: potential free, switching
- Electrical characteristics: 3A/125VAC; 3A/30VDC
Performance:
- Control over fire alarm loops and monitored outputs for fault conditions (short circuit and interruption) and automatic reset.
- Detection of removed devices in the loops and automatic reset.
- Ability to set the zones in Coincidence Mode.
- Two phases of Fire condition, programmable time for Fire condition stage I, separately for each zone.
- Option to prolong the time period for Fire condition stage I with programmable inspection period, specified for each zone.
- Built-in sounder for fire condition - one tonal, discontinuous, can be switched off.
- Built-in sounder for fault condition - one tonal, discontinuous, can be switched off.
- Built-in real time clock.
- Set of test modes and options for adjustment:
Setting the clock;
Check ups on light and sound indications;
Test of fire alarm zones;
Adjustment of outputs and integrated external devices;
Programming of parameters and modes of operation;
Remote programming of the parameters from distant operator control point.
- Energy independent archive of registered events with the events type, date and hour - up to 1023 events.
- Interfaces for communication with external devices - CAN 2.0B and RS-232 (directly or via modem).
Indications of registered events:
- Light indication: LED
- Text messages: LCD display, 320x240 points, backing
- Sound signaling: built-in sounder
Power supply:
- Mains:
Voltage: 220/230 V
Frequency: 50 Hz
- Back up batteries
Battery type: lead, gel electrolyte
Number of batteries: 2 pcs
Connection: Serial connection
Nominal voltage of the back up battery: 2 x 12V DC
Nominal capacity C20: 5 Ah
Charge voltage: 28V
- Consumption on back up batteries supply
At 24V: < 160 mA
At 26V: < 150 mA
- Power supply to external devices
Voltage: (24±5)V
Maximum current value (including current of monitored outputs): 1 A
- Dimensions: 286x148x125 mm
- Weight (batteries not included): 2,2 kg
Physical configuration:
- 1 fire alarm loop
- 2 monitored outputs
- 1 relay output for fire condition
- 1 programmable relay output for fire condition
- 1 relay output for fault conditions
Fire alarm zones:
- Maximum number of zones: 64
- Maximum number of fire detectors and in/out devices: 60
Fire alarm loop:
- Maximum number of fire detectors in a loop: 125
- Connecting line : two-wire shielded
- Maximum resistance of a loop: 100 ohm
- Output resistance of a loop: 20 ohm
- Maximum consumption of a loop: 200 mA
Monitored outputs: 2 pc
- Type: potencial
- Electrical characteristics: (24±5)V/0,5A
Relay output for fire conditions: 1 pc
- Type: potential free, switching
- Electrical characteristics: 3A/125VAC; 3A/30VDC
Relay (programmable) output for fire conditions: 1 pc
- Type: potential free, switching
- Electrical characteristics: 3A/125VAC; 3A/30VDC
Relay output for fault conditions: 1 pc
- Type: potential free, switching
- Electrical characteristics: 3A/125VAC; 3A/30VDC
Performance:
- Control over fire alarm loops and monitored outputs for fault conditions (short circuit and interruption) and automatic reset.
- Detection of removed devices in the loops and automatic reset.
- Ability to set the zones in Coincidence Mode.
- Two phases of Fire condition, programmable time for Fire condition stage I, separately for each zone.
- Option to prolong the time period for Fire condition stage I with programmable inspection period, specified for each zone.
- Built-in sounder for fire condition - one tonal, discontinuous, can be switched off.
- Built-in sounder for fault condition - one tonal, discontinuous, can be switched off.
- Built-in real time clock.
- Set of test modes and options for adjustment:
Setting the clock;
Check ups on light and sound indications;
Test of fire alarm zones;
Adjustment of outputs and integrated external devices;
Programming of parameters and modes of operation;
Remote programming of the parameters from distant operator control point.
- Energy independent archive of registered events with the events type, date and hour - up to 1023 events.
- Interfaces for communication with external devices - CAN 2.0B and RS-232 (directly or via modem).
Indications of registered events:
- Light indication: LED
- Text messages: LCD display, 320x240 points, backing
- Sound signaling: built-in sounder
Power supply:
- Mains:
Voltage: 220/230 V
Frequency: 50 Hz
- Back up batteries
Battery type: lead, gel electrolyte
Number of batteries: 2 pcs
Connection: Serial connection
Nominal voltage of the back up battery: 2 x 12V DC
Nominal capacity C20: 5 Ah
Charge voltage: 28V
- Consumption on back up batteries supply
At 24V: < 160 mA
At 26V: < 150 mA
- Power supply to external devices
Voltage: (24±5)V
Maximum current value (including current of monitored outputs): 1 A
- Dimensions: 286x148x125 mm
- Weight (batteries not included): 2,2 kg