The AC-88 is a wirelessly controllable intelligent socket. It can enable the remote switching of mains appliances (230V/50Hz/16A), boilers, electrical heaters, lighting, ventilation etc. The internal mains relay can be controlled by the unit's own button, RC-8x series Oasis remote controls, JA-8x series Oasis detectors, TP-8x series wireless thermostats, and the wireless PG output signals from JA-8xK series Oasis control panels, GD-04 David units, and EYE-02 security cameras (8 wireless control channels).
The unit can toggle its output, or switch on for a given time (1 minute to 24 hours). The AC-88 also has a built in transmitter, which means that a chain of slave AC-88s or other OASiS system devices (AC-82, UC-82, GD-04R wireless relays or JA-8xK control panels with JA-82R radio modules) can be formed so that the status of the master AC-88 can be copied by all the other enrolled devices.
Specifications
- Power supply: 230V/50Hz, safety class II
- Power consumption: approx 1W
- Communication frequency: 868 MHz, OASiS protocol
- Relay contact resistive load (cos Y =1): max.16A / 250V AC
- Relay contact inductive (capacitive) load (cosY=0.,4): max. 8A / 250V AC
- Maximum number of enrolled devices: 8
- Minimum transmitter distance: 1m
- Environment: II. indoor general (–10 to +40°C)
- Class of protection: IP40 according to EN 60529
- Mechanical resistance: IK08 according to EN 6626
- Dimensions: 64 x 91 x 45mm
- Conditions for operation: ERC REC 70-03
The unit can toggle its output, or switch on for a given time (1 minute to 24 hours). The AC-88 also has a built in transmitter, which means that a chain of slave AC-88s or other OASiS system devices (AC-82, UC-82, GD-04R wireless relays or JA-8xK control panels with JA-82R radio modules) can be formed so that the status of the master AC-88 can be copied by all the other enrolled devices.
Specifications
- Power supply: 230V/50Hz, safety class II
- Power consumption: approx 1W
- Communication frequency: 868 MHz, OASiS protocol
- Relay contact resistive load (cos Y =1): max.16A / 250V AC
- Relay contact inductive (capacitive) load (cosY=0.,4): max. 8A / 250V AC
- Maximum number of enrolled devices: 8
- Minimum transmitter distance: 1m
- Environment: II. indoor general (–10 to +40°C)
- Class of protection: IP40 according to EN 60529
- Mechanical resistance: IK08 according to EN 6626
- Dimensions: 64 x 91 x 45mm
- Conditions for operation: ERC REC 70-03